- Cabinet Style: Bench Top
- Nominal Widths: 4, 5, 6, 8 ft [1.2, 1.5, 1.8, 2.4 m]
- Dimensional Data:
- 3ft Model: 3' (91 cm), 350 lbs. (159 kg)
- 4ft Model: 4' (122 cm), 375 lbs. (170 kg)
- 5ft Model: 5' (152 cm), 450 lbs. (204 kg)
- 6ft Model: 6' (183 cm), 525 lbs. (238 kg)
- 7ft Model: 7' (213 cm), 600 lbs. (272 kg)
- 8ft Model: 8' (244 cm), 675 lbs. (306 kg)
- 10ft Model: 10' (305 cm), 855 lbs. (388 kg)
- 12ft Model: 12' (366 cm), 1045 lbs. (474 kg)
- 16ft Model: 16' (488 cm), 1410 lbs. (640 kg)
- Net Shipping Weight: 350 - 1410 lbs
- Certifications:
- ADA
- CFR 29, Part 1910
- SEFA 1
- NFPA 45
- ASTM E84-09C
- ASHRAE 110
- ANSI Z9.5
- UL 61010-1
- CAN/CSA C22.2 No. 61010-1
- UL 1805
- CE Conformity Marking (230V models)
- SEFA 8
- Access Opening: 18, 28in
- Electrical Requirements: 115 VAC / 60 Hz
- Total Exhaust CFM and Static Pressure @ 28" Sash Opening (100% Open)
- 3ft Hood:
- FPM- 100/CFM-495/s.p.- 0.13
- FPM-80/CFM-395/s.p.- 0.08
- FPM-60/CFM-295/s.p.- 0.05
- 4ft Hood:
- FPM- 100/CFM-725/s.p.- 0.27
- FPM-80/CFM-580/s.p.- 0.14
- FPM-60/CFM-435/s.p.- 0.10
- 5ft Hood:
- FPM- 100/CFM-955/s.p.- 0.34
- FPM-80/CFM-765/s.p.- 0.22
- FPM-60/CFM-575/s.p.- 0.12
- 6ft Hood:
- FPM- 100/CFM-1180/s.p.- 0.46
- FPM- 80/CFM-945/s.p.- 0.29
- FPM- 60/CFM-710/s.p.- 0.17
- 7ft Hood:
- FPM- 100/CFM-1410/s.p.- 0.23
- FPM- 80/CFM-1125/s.p.- 0.15
- FPM- 60/CFM-845/s.p.- 0.08
- 8ft Hood:
- FPM- 100/CFM-1640/s.p.- 0.31
- FPM- 80/CFM-1310/s.p.- 0.20
- FPM- 60/CFM-985/s.p.- 0.11
- 10ft Hood:
- FPM- 100/CFM-2100/s.p.- 0.45
- FPM- 80/CFM-1680/s.p.- 0.28
- FPM- 60/CFM-1260/s.p.- 0.16
- 12ft Hood:
- FPM- 100/CFM-2560/s.p.- 0.62
- FPM- 80/CFM-2050/s.p.- 0.39
- FPM- 60/CFM-1535/s.p.- 0.22
- 16ft Hood:
- FPM- 100/CFM-3500/s.p.- 0.37
- FPM- 80/CFM-2800/s.p.- 0.23
- FPM- 60/CFM-2100/s.p.- 0.13
- 3ft Hood:
- Total Exhaust CFM and Static Pressure @ 18" Sash Opening (62.5% Open)
- 3ft Hood:
- FPM- 100/CFM-310/s.p.- 0.05
- FPM-80/CFM-250/s.p.- 0.03
- FPM-60/CFM-185/s.p.- 0.02
- 4ft Hood:
- FPM- 100/CFM-450/s.p.- 0.11
- FPM-80/CFM-365/s.p.- 0.07
- FPM-60/CFM-270/s.p.- 0.04
- 5ft Hood:
- FPM- 100/CFM-595/s.p.- 0.13
- FPM-80/CFM-480/s.p.- 0.09
- FPM-60/CFM-360/s.p.- 0.05
- 6ft Hood:
- FPM- 100/CFM-735/s.p.- 0.18
- FPM- 80/CFM-590/s.p.- 0.11
- FPM- 60/CFM-440/s.p.- 0.07
- 7ft Hood:
- FPM- 100/CFM-880/s.p.- 0.09
- FPM- 80/CFM-705/s.p.- 0.06
- FPM- 60/CFM-525/s.p.- 0.03
- 8ft Hood:
- FPM- 100/CFM-1025/s.p.- 0.12
- FPM- 80/CFM-820/s.p.- 0.08
- FPM- 60/CFM-615/s.p.- 0.04
- 10ft Hood:
- FPM- 100/CFM-1300/s.p.- 0.17
- FPM- 80/CFM-1050/s.p.- 0.11
- FPM- 60/CFM-800/s.p.- 0.06
- 12ft Hood:
- FPM- 100/CFM-1585/s.p.- 0.24
- FPM- 80/CFM-1280/s.p.- 0.16
- FPM- 60/CFM-970/s.p.- 0.09
- 16ft Hood:
- FPM- 100/CFM-2170/s.p.- 0.14
- FPM- 80/CFM-1750/s.p.- 0.09
- FPM- 60/CFM-1330/s.p.- 0.05
- 3ft Hood:
Labconco Protector XL Benchtop Laboratory Fume Hoods
Item#: PROTECTORXLThe Protector XL Benchtop Laboratory Hoods are general chemistry hoods that offer superior design flexibility. They are available in widths from 3 to 16 feet and three depths to meet a variety of installation and application requirements. These hoods incorporate containment-enhancing features allowing them to operate at face velocities as low as 60 fpm and meet the SEFA-1 standard of a low velocity high performance hood.
- By-pass airflow design
- Eco-Foil? air foil with aerodynamic Clean-Sweep? airflow openings*
- Cord-Keeper? slots on left and right side of air foil
- Glacier white powder-coated steel exterior
- Chemical-resistant, fiberglass-reinforced, composite panel liner and baffle
- Opti-Zone? baffle* with flame spread index less than 25 per ASTM E84**. Baffle is removable for cleaning
- Tempered safety glass vertical-rising sash and cable and pulley
- Powder-coated aluminum sash handle with Clean-Sweep? openings*
- 37.5" (95.3 cm) high sightline from the work surface and header panel
- Removable front and side panels, and front and interior service panels for access to plumbing and electrical wiring
- Pre-wired LED lighting with vapor-proof design and ADA-compliant light and blower switches. Lighting rated for 50,000 hours
- Powder-coated stainless steel, 12.81" (32.5 cm) ID exhaust connection(s)
- Standards conformance & regulations:
- ADA
- CFR 29, Part 1910
- SEFA 1
- NFPA 45
- ASTM E84-09C
- ASHRAE 110
- ANSI Z9.5
- UL 61010-1
- CAN/CSA C22.2 No. 61010-1
- UL 1805
- CE Conformity Marking (230V models)
- SEFA 8
- WARNING: Cancer - P65Warnings.ca.gov (California only)
- 8' models available with:
- Optional split dual tempered safety glass vertical-rising sashes with cable and pulleys and powder-coated sash handles
- 10', 12' and 16' models feature:
- By-pass block
- Split dual tempered safety glass vertical-rising sashes with cable and pulleys, powder-coated sash handles and 10" (25.4 cm) high static viewing windows to permit the sashes to be fully raised without extending above the hood. Four sashes on 16' models
- Fixtured models feature:
- Two pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided
- One pre-wired GFCI electrical duplex receptacle on lower right side and, on 8' and larger models only, one additional pre-wired GFCI electrical duplex on lower left side
- Required accessories (not included):
- Remote blower
- Ductwork
- Work surface
- Base cabinet or stand
- Optional accessories for on-site installation include:
- Service Fixture Kits
- Electrical Duplex Kits
- Guardian Airflow Monitor Kits
- Sash Stop Kits
- Ceiling Enclosure, Rear Finish Panel Kits and Distillation Grid Kits